想要提高粗纖維檢測精度,這幾點要注意了!
隨sui著zhe人ren們men生sheng活huo水shui平ping的de不bu斷duan提ti高gao,消xiao費fei者zhe們men對dui食shi品pin的de品pin質zhi也ye發fa生sheng了le明ming顯xian的de變bian化hua。從cong過guo去qu的de能neng吃chi飽bao就jiu行xing,到dao如ru今jin不bu僅jin要yao吃chi得de安an全quan,而er且qie要yao好hao吃chi有you營ying養yang。尤you其qi是shi對dui食shi品pin中zhong蛋dan白bai質zhi含han量liang、脂肪含量、粗纖維含量等指標。因此,這也使得許多食品生產加工企業積極地采用粗纖維測定儀等重要的品質檢測儀器開展品質質檢工作,從而品質化生產,滿足消費者需求,獲取穩定效益。

shouxianwomenyaolejiedeshi,cuxianweicedingyishiyikuanzhuanyeyongyucedingshipincuxianweihanliangdeyiqi,erqiexiangbijiaoyuchuantongdecedingfangfa,zhezhongsuanjianxiaozhuchengzhongdefangfagengjiajingzhunqiecaozuogengjiajiandan。dangran,zaicuxianweicedingyideshijicaozuoguochengzhong,haishiyouxuduoyonghuyinweiduigaiyiqidecaozuobugouguifan,yizhiyuyiqishoumingyijijiancejingzhundudoudadazhekou。yinci,xiaobianjintianzhuyaofenxiangyixiaguanyucuxianweicedingyidezhengqueshiyongfangfa,wangdajiayousuocankao:
1、在坩堝內放入1-2g(精確到0.0002g)試樣,並將裝好式樣的坩堝分別放入6個抽濾座中,緩慢按下升降手柄,確保抽濾底杯,坩堝和消煮管相互對正,以免損壞玻璃;
2、打開左側進水開關,向冷凝管中注水,水量適中;通上220V電源,往燒瓶中放入不低於2000ml相應的試劑,確保所有開關閥門處於關閉狀態(橫向為關閉);
3、打開電源總開關以及酸預熱,堿預熱和水預熱開關,並調節預熱調壓旋鈕至最大,電壓值220V左右,待燒瓶內酸、堿、蒸餾水沸騰;調節預熱電壓旋鈕,將電壓調至150V-170V左右,至酸、堿、蒸餾水微沸;
4、關閉酸預熱開關,將擋熱板緊靠在加熱盒前麵,打開消煮加熱開關,將消煮調壓旋鈕調至最大220V左右,待消煮管內酸液沸騰,將消煮電壓調至150-170V,使酸液保持微沸,打開上方定時器開關,定時30分鍾;30分鍾後,蜂鳴器報警,關閉消煮加熱開關與定時器,將消煮調壓旋鈕逆時針調到底,取下擋熱板;
5、打開抽濾開關,打開抽濾閥門,接著依次打開6個消煮管對應閥門;蒸餾水和堿消煮工作依次完成之後,用吸管分別在消煮管內加入25ml左右95%乙醇,浸泡十幾分鍾後抽幹,完成後關閉電源總開關,進行後續清潔工作。