羅維朋比色計六大誤差原因及解決方法
羅維朋比色計是shi一yi種zhong目mu視shi顏yan色se的de測ce量liang儀yi器qi,它ta也ye是shi目mu前qian國guo際ji公gong認ren較jiao有you權quan威wei性xing的de專zhuan用yong儀yi器qi,通tong過guo目mu視shi顏yan色se匹pi配pei方fang法fa測ce定ding物wu質zhi顏yan色se,廣guang泛fan應ying用yong於yu塑su料liao,紡fang織zhi,食shi品pin,糧liang食shi等deng物wu質zhi顏yan色se的de測ce量liang。我wo們men都dou知zhi道dao,無wu論lun哪na種zhong儀yi器qi,都dou會hui因yin為wei人ren為wei的de操cao作zuo不bu當dang導dao致zhi試shi驗yan結jie果guo的de產chan生sheng誤wu差cha,這zhe些xie常chang會hui給gei企qi業ye帶dai來lai不bu必bi要yao的de麻ma煩fan,如ru對dui實shi際ji測ce定ding結jie果guo有you異yi議yi,也ye可ke以yi把ba儀yi器qi送song到dao專zhuan業ye的de計ji量liang部bu門men,進jin行xing仲zhong裁cai檢jian定ding。為wei了le避bi免mian由you於yu測ce定ding結jie果guo不bu準zhun確que造zao成cheng的de一yi係xi列lie問wen題ti,小xiao編bian在zai這zhe裏li還hai是shi有you必bi要yao和he大da家jia講jiang解jie一yi下xia關guan於yu羅luo維wei朋peng比bi色se計ji的de誤wu差cha原yuan因yin,一yi般ban有you以yi下xia影ying響xiang因yin素su:

1.底色不均勻造成的影響,觀察前,應該對底色不均勻進行檢查,方法是檢查標準白板是否一致、光源前的毛玻璃是否被汙染、目鏡及光源是否被汙染等。
2.不bu同tong觀guan察cha者zhe造zao成cheng的de影ying響xiang,在zai實shi際ji操cao作zuo中zhong,由you於yu該gai儀yi器qi是shi目mu視shi儀yi器qi,不bu同tong的de觀guan察cha者zhe有you可ke能neng得de到dao的de測ce定ding結jie果guo不bu一yi致zhi,為wei了le減jian小xiao人ren為wei引yin起qi的de測ce量liang誤wu差cha,可ke以yi找zhao3個色覺正常的人,在同一環境、使用同一台儀器、背對背測量同一樣品,取3個測量值的平均值作為測量結果。
3.儀器使用不當造成色差的影響,由於標準濾光片是用有色玻璃製成的,使用不當會使其被汙染。
4.觀察者心理因素造成色差影響,顏色是一個心理、生理、物理量,它與一個人的心理因素有很大關係,尤其是在測量小色號樣品時,表現更為明顯。
5.連續測量造成的影響,觀察時間長了,人眼的分辨力降低了。在測量時,對某顏色注視片刻 ,迅速將視線離開,注視遠方片刻,再進行下一次測量。
6.兩liang光guang源yuan不bu一yi致zhi造zao成cheng的de影ying響xiang,羅luo維wei朋peng比bi色se計ji使shi用yong的de時shi間jian如ru果guo過guo久jiu,那na麼me燈deng泡pao會hui自zi然ran損sun壞huai。若ruo燈deng泡pao損sun壞huai,兩liang隻zhi燈deng泡pao應ying同tong時shi更geng換huan,更geng換huan時shi應ying測ce量liang兩liang燈deng泡pao的de工gong作zuo電dian流liu,其qi差cha值zhi應ying不bu大da於yu5mA。
以yi上shang六liu點dian就jiu是shi關guan於yu羅luo維wei朋peng比bi色se計ji的de誤wu差cha原yuan因yin,小xiao編bian在zai對dui應ying影ying響xiang因yin素su的de後hou麵mian也ye為wei大da家jia簡jian單dan的de介jie紹shao了le解jie決jue方fang法fa,希xi望wang在zai實shi際ji操cao作zuo中zhong,能neng給gei大da家jia帶dai去qu幫bang助zhu。